Online SO2 NOX Analyzer
Online SO2 NOX Analyzer
Send Inquiry
Product Code : GMS-SO2-NOx-IR
Product Description

Online SO2 NOX Analyzer

Model: GMS-SO2-NOx-IR

Salient Features:

  • Measurement based on NDIR Technique
  • Fast and reliable analysis
  • Inbuilt data logging system ensures no loss of data. 
  • Easy and minimum maintenance due to its extraction type of measurement.
  • Programmed for automatic purging of sampling probe.
  • Analog as well as digital data communication.
  • Data Communication through 4-20 mA, RS 232/RS 485
  • Built-in zero air generator for instrument zeroing
  • Auto/remote calibration facility

Technical Specification:

  • Measurement Method: NDIR Sensor
  • Measuring Range SO2/NOx: 0 - 2000 ppm  
  • Resolution: 1 ppm
  • Data Display: HMI display
  • Communication port: RS 232/RS 485
  • Current output: 4-20 mA
  • Data  Logging: Supports Internal Logging
  • Power: 230 VAC 

Peltier Probe (Heated Sampling Probe with sample Conditioning System)
 
Contact part made of SS 316 and assembled with filter.  Specially designed Peltier cooling system makes the sample gas which is carried out to analyzer by Teflon tubing.
 
Technical Specification of Peltier probe:

  • Gas temperature at inlet: Up to 400 ⁰C
  • Ambient temperature:  3-50 ⁰C
  • Dead space per gas path: 10 ml
  • Outlet sample gas dew point:  < 5 ⁰C
  • Heat Exchanger material:  SS 316L/ Quartz
  • Cooling  Block: Aluminium
  • Catch-pot volume: 200 ml
  • Dimensions (BxHxT):  400x400x150 (in mm)
  • Housing:  Stack mountable, SS316L Enclosure
  • Power supply: 230V AC
  • Power consumption : ~280W

Teflon Tube for sampling line(100 Mtrs) Protection Conduct Tube for protecting Teflon tube

Unique Benefits of Peltier Probe
 
Peltier probe system offers an economical solution compared to the conventional heating system as the moisture from the gas is removed at the stack itself due to which the use of Heated sampling line is completely eliminated which brings down the daily power consumption and cuts down the annual running cost.By using Uniphos Peltier Probe technology we completely eliminate the use of heated sample line and use only normal teflone tubing.

Considering 100 Meter of heat traced line,per day running cost will Rs.1000 to 1500/ day in terms of electricity which sums upto Rs 3,65,000.00 approx. per year ie.the amount spent on power consumption by the “heat traced line” .Weheas peltier probe “ELIMINATES” this power consumption as we are not using any heat traced line.